FREE 1 to 3-Day Delivery on Orders $119+ Details
Step 1:
Remove the 10mm bolts holding the coolant overflow to the fan shroud. Move the overflow out of the way so that you can access the supercharger belt tensioner.
Step 2:
Using a 3/8” ratchet apply pressure so that you can remove the Super charger belt from the pulley. **Note: Just fold the belt out of the way, there is no need to remove it.
Step 3:
Remove the (3) 8mm bolts on the coolant housing (directly below the supercharger pulley). Mount the new bracket using the supplied allen (5mm) head bolts. Torque to 15 ft-lbs.
Step 4:
Reinstall the supercharger belt. **Note: You may need an extra hand as the belt will be more difficult to slip behind the tensioner. Make sure the belt is aligned correctly on all other pulleys.